OPTIMIZACIÓN DEL SISTEMA DE ACUEDUCTO PERTENECIENTE AL CORREGIMIENTO LOS PONDORES DEL MUNICIPIO DE SAN JUAN DEL CESAR, LA GUAJIRA
dc.contributor.author | CARRILLO CAMACHO, IRINA; VEGA TRIANA, ROSA GISELA | |
dc.date.accessioned | 2025-07-27T00:03:54Z | |
dc.date.available | 2025-07-27T00:03:54Z | |
dc.date.issued | 2022 | |
dc.description.abstract | El presente documento muestra la planificación y metodología aplicadas en la optimización del sistema de acueducto para el corregimiento Los Pondores. Inicialmente, se recolectó información acerca de la población de estudio relacionada a los aspectos relevantes para el desarrollo de la investigación, como lo es el conocimiento y uso que le dan a los distintos servicios de saneamiento básico existentes y número de habitantes, evidenciando que la población no cuenta con facturación del servicio de acueducto. Posterior a esto, se estimaron las demandas poblacionales para poder determinar los caudales de diseño. Se midieron parámetros fisicoquímicos y microbiológicos para determinar estas condiciones en el agua, además se determinó si estos resultados están dentro de los límites permisibles por la normatividad vigente colombiana. En secuencia, se llevó a cabo una estimación del caudal de aforo en los tanques de almacenamiento para conocer la capacidad instalada en el sistema actual dando como resultado un exceso en el caudal, es decir, el agua que pasa por el sistema es mayor al caudal proyectado en el periodo de diseño. Se propuso un sistema de desinfección basado en la inyección de solución de HTC en la tubería de aducción, logrando niveles requeridos de cloro residual en el agua previamente esta sea enviada a la red de distribución gracias al tiempo de retención hidráulico de cada tanque. Por último, se realizó la simulación hidráulica de la red de distribución en el software EPANET. Este proyecto se elaboró basándose en los lineamientos establecidos por la resolución 0330 de 2017. ABSTRACT This document shows the planning and methodology applied in the optimization of the aqueduct system for the Los Pondores township. Initially, information was collected about the study population related to the relevant aspects for the development of the research, such as the knowledge and use that they give to the different existing basic sanitation services and the number of inhabitants, showing that the population does not has billing for the aqueduct service. After this, the population demands were estimated in order to determine the design flows. Physicochemical and microbiological parameters were measured to determine these conditions in the water, it was also determined if these results are within the permissible limits by current Colombian regulations. In sequence, an estimation of the capacity flow in the storage tanks was carried out to know the installed capacity in the current system, resulting in an excess in the flow, that is, the water that passes through the system is greater than the projected flow in the design period. A disinfection system based on the injection of HTC solution in the adduction pipe was proposed, achieving required levels of residual chlorine in the water before it is sent to the distribution network thanks to the hydraulic retention time of each tank. Finally, the hydraulic simulation of the distribution network was carried out in the EPANET software. This project was developed based on the guidelines established by resolution 0330 of 2017. Palabras clave: Acueducto, desinfección, EPANET, cloro residual, agua potable, caudal de diseño, resolución 0330 de 2017. Keywords: Aqueduct, disinfection, EPANET, residual chlorine, drinking water, design flow, Resolution 0330 of 2017. | |
dc.identifier.uri | http://repositorio.unicesar.edu.co/handle/123456789/1751 | |
dc.language.iso | es | |
dc.title | OPTIMIZACIÓN DEL SISTEMA DE ACUEDUCTO PERTENECIENTE AL CORREGIMIENTO LOS PONDORES DEL MUNICIPIO DE SAN JUAN DEL CESAR, LA GUAJIRA |